Sensor parameters
Sensor parameters | |
---|---|
NAME | DESCRIPTION |
SENSOR_OK | 1 if SENSOR_LIMITS, ENV_VIBRATION, ENV_TEMPERATURE and SENSOR_HEALTH is 1. |
SENSOR_HEALTH | 0 if any of the follow occurs:
This error usually means a malfunctioning sensor which needs repair or replacement if error does not disappear after reboot. |
SENSOR_LIMITS | 0 if any of the gyroscopes or accelerometers has been saturated. The SENSOR_LIMITS is returned to 1 after 60 s after all sensors are within range again. |
ENV_VIBRATION | 1 if the noise variance of the accelerometer length vector is less than 0.5 g with a window duration of 3 s. Move the MRU to a location with less vibration for increased performance if this status bit is 0. |
ENV_TEMPERATURE | 1 if the sensor temperature is in the range -40 to 85 degrees Celsius. |