Skip to main content
Skip table of contents

MRU Marine/Subsea configuration file

Parameters and associated default (factory) values for the MRU Marine/Subsea configuration file.

udpStreamers

MRU configuration file - udpStreamers

Parameter (level 1)

Factory value

host

10.0.0.100

port

2001

host

10.0.0.100

port

2002

host

10.0.0.100

port

2003

network

MRU configuration file - network

Parameter (level 1)

Factory value

ipaddrmode

static

ip

10.0.0.50

subnetmask

255.255.0.0

gateway

0.0.0.0

dns

0.0.0.0

linkspeed

100full

input

MRU configuration file - input

Parameter (level 1)

Factory value

aid1

Aid_Abstract

aid2

Aid_Abstract

parser1_udp

NMEA

port1_udp

2044

parser2_udp

NMEA

port2_udp

0

output

MRU configuration file - output

Parameter (level 1)

Parameter (level 2)

Factory value

streamer1

-

Streamer_UDPs

streamer2

-

Streamer_RS232

streamer3

-

Streamer_Abstract

commander2

-

Commander_RS232

variableList

-

[124 125 126 133 134 147]

protocol

-

NORSUB6

rate

-

50

location

-

MRU

usemode

-

General Purpose

numberFormat

-

%.3f

id

-

$PSXN

token

-

19

tokenEnabled

-

true

statusEnabled

-

true

serial

-

RS-232

modbusTCP

registerType

0

ethernetIP

instanceID

110

installation

MRU configuration file - installation

Parameter (level 1)

Parameter (level 2)

Factory value

orientation

mainRotationAngles

[0 0 0]

offsetAngles

[0 0 0]

position

cg

[0 0 0]

mruPosition

[0 0 0]

monitoringPoints

remoteMode

Virtual MRU

monitoringPoint1

[0 0 0]

monitoringPoint2

[0 0 0]

time

MRU configuration file - time

Parameter (level 1)

Parameter (level 2)

Factory value

pps

enabled

true

zdaoffset

1

zdapolarity

true

zdadec

1

ntp

enabled

false

ntpMode

0

serverList

oops

rs232

MRU configuration file - rs232

Parameter (level 1)

Factory value

baudrate

115200

databits

8

parity

0

stopbits

10

flowcontrol

0

rs485

MRU configuration file - rs485

Parameter (level 1)

Factory value

baudrate

921600

databits

8

parity

0

stopbits

10

flowcontrol

0

parameters

MRU configuration file - parameters

Parameter (level 1)

Parameter (level 2)

Factory value

invertAxes

roll

false

pitch

false

yaw

false

surge

false

sway

false

heave

false

geo

MRU configuration file - geo

Parameter (level 1)

Factory value

latitude

60

declination

0

filter

MRU configuration file - filter

Parameter (level 1)

Factory value

gyroaccfc

1

enableyawfilter

1

yawhpwc

0.006283

yawfilter2order

0

analog

MRU configuration file - analog

Parameter (level 1)

Factory value

enabled

false

mode

Volt

test

On

value

5

gains

[1, 1, 1, 1, 1, 1]

offsets

[0, 0, 0, 0, 0, 0]